Electrical Input |
Nominal Voltage |
230 VAC |
Voltage Range |
100-300 VAC |
Frequency |
50 / 60 Hz Auto-sensing |
Frequency range |
40-70 Hz |
Input Connection - all models |
IEC 320-C19 Input receptacle |
Input Power Factor |
>0.95 @ nominal voltage |
Earth Leakage |
3.5mA, Max |
|
|
Electrical Output |
Output Voltage |
230 VAC (208/220/230/240 VAC -
User selectable) |
Voltage Regulation |
± 1% of nominal |
Output Frequency |
50 or 60 Hz - user selectable |
Frequency Regulation |
± 0.5% |
Efficiency |
88-92% depending on load |
Receptacles -PP+
1500 |
(7) Country specific receptacles or (10) Hubbell NEMA 5-15R |
Receptacles -
PP+ 2000/3000 |
(7) Country specific
output receptacles + (2) Hubbell L6-15R or
(10) Hubbell NEMA 5-15/20R + (2) Hubbell L6-15R |
Optional receptacles |
Furutech High
Performance Receptacle - avail for NEMA model |
Standby power
consumption |
10 watts |
Output
Power - PP+ 1500 |
1350 watts continuous / 1750 short
term (2 min.) / 2700 (10 sec.) / 6750 (inst.) |
Output
Power - PP+ 2000 |
1800 watts continuous / 2340 short
term (2 min.) / 3600 (10 sec.) / 9000 (inst.) |
Output
Power - PP+ 3000 |
2700 watts continuous / 3510 short
term (2 min.) / 5400 (10 sec.) / 13,500 (inst.) |
|
|
Physical Characteristics
|
Form Factor |
Standalone or Rack mountable |
PP+ 1500 - Single module |
13 h x 42 w x 42 w cm. 19Kg
Ship wt 22Kg |
PP+ 2000 - Regen. module |
13 h x 42 w x 42 d cm, 13Kg Ship wt
16Kg |
PP+ 2000 - PowerPack Mod. |
9 h x 42 w x 42 d cm, 17Kg
Ship wt 19Kg - both module 34Kg |
PP+ 3000 - Regen. module |
13 h x 42 w x 42 d cm, 13Kg
Ship wt - 18Kg |
PP+ 3000 - PowerPack Mod. |
9 h x 42 w x 42 d cm,
22Kg Ship wt 24Kg - both module 42Kg |
|
|
Environmental and Safety |
Safety Markings |
CE |
EMC monitors |
FCC Class B and VCCI Class II |
Surge Suppression |
IEEE / ANSI C62.41 Category B (formerly 587) |
Ambient Operating Temp. |
32 - 90• F (0 - 32•C) |
Audible noise |
<15 dBA |
Relative humidity |
0 to 90% non-condensing |
|
|
Additional Features |
F-Type (coax) surge protection |
2 input, 2 output |
Phone line surge protection |
1 line input RJ11 |
RJ 45 Transient protector |
Input and output jack for RJ-45 cable protection,
UL497A tested |
User selectable bypass |
Bypass mode may be selected at any time. Automatic bypass on
sustained overload |
Diagnostics |
Full system self-test on power up, user selectable diagnostics
at any time |
|
|